Replacing a Gas Furnace and Separate AC With One Heat Pump

Key takeaway: One heat pump system absorbs both machines. The outdoor unit keeps the compressor and coil work an air conditioner was already doing and adds a reversing valve so the same refrigerant circuit can run in heating, while the furnace cabinet is replaced by an air handler carrying an electric backup heat package instead of burners. Three items decide how big the project gets, the gas water heater left venting alone in a shared chimney, the 240 volt feeder the strip heat needs, and the airflow the existing ducts can actually carry. TerraStream Energy does this conversion for Maryland homeowners, with Prince George's County first, and puts the plumbing and electrical pieces that belong to other trades on the proposal before any equipment is ordered.
What Leaves the House and What Arrives
The Furnace Ran in One Direction Only
A gas furnace makes heat and a heat pump moves heat, and that single difference is why almost nothing inside the furnace cabinet has a place in the new system. Pull the front doors off a 20 year old furnace and you are looking at a gas valve, a burner assembly, a hot surface igniter, a steel heat exchanger, an inducer motor that drags exhaust out through the flue, and a blower sitting at the bottom of the cabinet.
The heat exchanger is the part that matters most. House air passes over the outside of it, combustion gases pass through the inside, and a wall of steel keeps the two apart for twenty winters until a crack opens along a seam somewhere.
Efficiency on that machine gets rated as AFUE, short for Annual Fuel Utilization Efficiency, the share of the fuel's energy that ends up in the rooms over a heating season instead of going out the flue.
Exactly one piece of that cabinet has a counterpart in a heat pump system, and it is the blower. The Department of Energy describes a heat pump as equipment that transfers heat from one place to another rather than generating it, which is why the burners, the gas valve, the igniter, the heat exchanger, the inducer, the pressure switches and the flue collar have no successor in the new system. What the next machine inherits is the sheet metal above and below the cabinet and the ducts bolted to it.
The Condenser Outside and the Coil Upstairs
The outdoor air conditioner and the coil sitting on top of the furnace already contain most of a heat pump. Out on the pad there is a compressor, a coil wrapped around the inside of the cabinet, a fan pulling air up through that coil, and a metering device. Indoors, bolted into the supply plenum directly above the furnace, sits the evaporator coil. Two copper lines run between them through the band joist, one fat and insulated, one thin and bare, and that pair is called the line set.
Cooling runs one way only. Refrigerant picks up heat from house air at the indoor coil, the compressor raises its pressure and temperature, and the outdoor coil dumps that heat into the back yard.
Ratings on the newer version of this equipment read as SEER2, a seasonal cooling efficiency number measured under a test procedure that uses realistic duct static pressure, which is why a SEER2 figure comes out a little lower than the old SEER number for the same machine. Most air conditioners installed in Maryland basements before about 2024 hold R-410A refrigerant. The federal phasedown of high global warming refrigerants under the EPA's AIM Act is the reason new residential equipment ships with something else.
Compressor, coils, fan, refrigerant circuit, thermostat wiring, condensate drain. A heat pump keeps every one of those, adds a single valve, and changes what the indoor box is.
What Physically Gets Hauled Away
Removal day strips the mechanical space down to bare duct connections, a condensate line, a dead gas pipe and two electrical whips. The furnace cabinet comes out in one piece or in two, depending on the stairwell. Up top, the evaporator coil comes off the plenum, which means cutting the sheet metal transition apart and rebuilding it to fit the new cabinet, since coil and plenum dimensions rarely match across brands or across decades.
Outside, the condenser gets its charge recovered, then it is disconnected, unbolted from the pad and carried out. TerraStream Energy pulls that refrigerant into a recovery cylinder before a single joint is unbrazed, because venting refrigerant to atmosphere during service or removal is prohibited under Section 608 of the Clean Air Act.
The line set is the one real judgment call. Copper that is correctly sized, in good condition and running a short path can sometimes stay and be flushed. Tubing that is undersized for the new equipment, kinked behind a joist, or buried in a wall with no access gets replaced, and on any house where the old charge was R-410A the installer has to confirm the existing tubing is rated for the higher operating pressure the new refrigerant works at.
Gone by the end of the day as well are the old condenser pad, the flue pipe between the furnace and the chimney thimble, the furnace filter rack, and in almost every case the thermostat, since a heat pump needs a thermostat with a reversing valve output and a second stage for backup heat.
Job in the house | Furnace and air conditioner | Single heat pump system |
|---|---|---|
Making winter heat | Gas burners and a steel heat exchanger | Outdoor compressor and the refrigerant circuit running in reverse |
Making summer cooling | Outdoor condenser and indoor evaporator coil | The same outdoor unit and indoor coil, unchanged in cooling mode |
Moving air through the ducts | Blower in the bottom of the furnace cabinet | Blower in the air handler cabinet |
Heat on the coldest nights | Burners fire for longer cycles | Electric resistance elements inside the air handler |
Getting exhaust out of the house | Inducer, flue pipe, chimney liner | Nothing, since no combustion happens |
Fuel supply | Gas pipe, shutoff valve, flex connector | One electrical feeder plus the outdoor circuit |
Switching between heating and cooling | Two separate machines, two separate calls | One reversing valve inside the outdoor unit |
Which jobs move from the furnace and air conditioner pair into one heat pump system

One Machine That Runs Both Directions
The Reversing Valve Is the Whole Trick
A heat pump is an air conditioner with a four way valve that decides which coil gets hot. The compressor only ever does one thing. It squeezes refrigerant vapor into a high pressure, high temperature gas. Where that gas goes next is the open question, and a brass valve about the size of a soda can answers it.
In cooling, the valve sends hot discharge gas out to the condenser coil, which rejects heat to the outdoor air. Flip to heating and a solenoid shifts a small pilot valve, pressure moves a slide inside the valve body, and the same hot gas goes to the indoor coil instead. House air blowing across that coil picks the heat up. The outdoor coil becomes the cold one, absorbing heat out of 30 degree winter air, which sounds impossible until you remember that 30 degree air still holds a great deal of heat relative to refrigerant boiling at 10 degrees.
Homeowners hear this valve work. A soft thump followed by a rush of refrigerant noise out at the unit when the system changes modes is the slide moving, and it is normal.
Two ratings describe how well the machine does that job. COP, the coefficient of performance, is the ratio of heat delivered to electricity consumed at a given moment. HSPF2, the Heating Seasonal Performance Factor, is the seasonal version printed on the label. ENERGY STAR's air source heat pump criteria list the levels that currently qualify, and those thresholds get revised, so a label from five years ago does not compare cleanly against one printed this year.
The Indoor Unit Becomes an Air Handler
What takes the furnace's place in the basement is a cabinet holding a blower, a coil, a filter rack and a control board, with no combustion anything. The trade name for that box is an air handler. It runs quieter than a furnace, it is frequently shorter, and nothing sits on top of it where the flue collar used to be.
Orientation still matters. The cabinet gets set up as upflow when it sits on the floor and blows into a plenum above. Downflow is the version that blows into a crawlspace or a slab duct below, and horizontal is the one that hangs in an attic or lies on its side in a tight basement. Furnaces came in those same configurations, so the new cabinet usually lands in the old footprint with new sheet metal transitions top and bottom.
Inside, the coil stops being a cooling-only part. It condenses refrigerant in winter and evaporates it in summer, so it runs hot roughly half the year and the drain pan and condensate path get checked for both seasons. A variable speed blower motor is standard on the better air handlers and it changes how the system feels more than most homeowners expect, since the fan ramps up over 30 seconds or so instead of slamming on at full speed.
One thing the air handler does not have is a draft inducer, and the loss of that fan matters far more up in the chimney than it does down in the basement.
Electric Backup Heat Lives in That Cabinet
The air handler carries a strip heat package, a bank of electric resistance elements mounted in the airstream right above the blower. They look like oversized toaster coils bolted into a sheet metal frame, rated in kilowatts rather than BTUs, with sequencers that bring them on in stages and high limit switches that cut them out if airflow stops.
Those elements exist for three specific moments. The first is weather below the system's balance point, which is the outdoor temperature where the heat pump's output drops to exactly what the house is losing. Under that temperature the heat pump alone cannot hold the thermostat setting and the strips fill the gap. Second comes defrost, when the system runs briefly in cooling mode to melt frost off the outdoor coil and the strips temper the supply air so the registers do not blow cold into the living room. Third is a failure of the outdoor unit, which is what the Emergency Heat setting on the wall is for.
Electric resistance heat turns the electricity it draws into heat at the point of use with no stack loss at all, and it is still an expensive way to heat a house compared with a heat pump moving that same heat. A correctly sized heater kit and a sensible lockout, so the strips stay off on a 45 degree afternoon, make the difference between a conversion that behaves itself and one that produces a startling January bill.
Dual fuel, for comparison, keeps the gas furnace in place and fires it instead of strips below the balance point. That is a different project with a live gas line still in the basement, and it is not the swap this article describes.
The Gas Line, the Flue, and the Chimney
Capping the Pipe That Fed the Furnace
The gas branch serving the furnace gets shut at its valve, disconnected, capped and left dead in place. On a basement install that means closing the shutoff above the drip leg, taking off the flexible connector, and threading a cap onto the tee so the pipe is sealed and visibly out of service. The branch itself stays up in the joists, since tearing out black iron buys nothing.
What happens to the rest of the gas service depends on what else in the house still burns. A water heater, a range, a dryer or a fireplace log set keeps the meter in place and the service active. Any house where the furnace was the last gas appliance can go all the way off the fuel, and the utility removes the meter on request, which is a transaction between the homeowner and the utility rather than something a contractor does.
Pipe work past the appliance connection belongs to a licensed gas fitter or plumber. That trade abandons a long run or relocates a meter, and a homeowner should expect a separate scope for it rather than assuming an HVAC crew will take on the plumbing side of the house.
The Water Heater Left Venting Alone
A gas water heater that shared the chimney with the furnace is left venting by itself into a flue that was never sized for one appliance, and that is a combustion safety condition which has to be corrected as part of the same project. Installers call that appliance orphaned.
A standard atmospheric water heater has no fan. It relies on hot exhaust rising through a draft hood and up the flue, and that rise depends on the flue staying warm. For decades the furnace did the warming. Every time the burners fired, a large volume of hot gas pushed up the same masonry chimney and kept the liner hot, and the water heater's small, cool exhaust rode along on that current.
Take the furnace out and a 40 gallon water heater is suddenly trying to drive its own draft up a flue with several times the cross section it needs. Nothing warms that masonry now. Exhaust cools, slows and condenses on the liner walls, and acidic condensate chews at mortar and at metal. On a windy day the draft can reverse outright and spill flue gases at the draft hood, which puts carbon monoxide into the basement. The EPA's summary of carbon monoxide indoors is blunt about why that matters at low concentrations, long before anybody smells anything.
Vent sizing for this condition is governed by the tables in the National Fuel Gas Code, published as NFPA 54 and ANSI Z223.1, and those tables are where a correctly sized liner comes from. Three fixes are real. Reline the chimney with a metal liner sized for the water heater alone. Replace the water heater with a sealed combustion, power vented or direct vent model that vents out a sidewall and ignores the chimney entirely. Or take the water heater electric, which is where a heat pump water heater enters the conversation and the chimney goes out of service for good.
All three of those are plumbing and chimney work. Plumbers set water heaters, and a chimney contractor or a mason installs the liner. TerraStream Energy identifies the orphaned appliance before the furnace leaves the basement, puts it in writing, and sequences the job so no household spends a heating season drafting into a cold oversized flue.
"The furnace comes out in an afternoon. What I slow a job down for is the water heater hanging on that chimney, because the flue was sized for two appliances and it is about to have one, and a weak draft does not announce itself." Jake Mazzoccoli, Owner, TerraStream Energy
What Happens to the Chimney Itself
The furnace flue pipe comes out, the hole through the chimney wall gets sealed, and the chimney either gets relined for whatever is still vented into it or gets taken out of service. Those are the two honest outcomes, and which one applies follows directly from the water heater decision.
A flue that still serves an appliance needs its liner sized to that appliance, the thimble sealed around the new connector, and the cap intact up at the top. An abandoned flue still needs rain kept out, which means a cap and a sealed thimble, because an unused masonry flue with no warm gas moving through it collects moisture, and moisture plus Maryland freeze and thaw cycles is what spalls brick and pushes a crown apart.
Fireplaces are a separate matter. A fireplace almost always has its own flue inside the same chimney stack, and nothing about removing a furnace changes that flue. Ask a chimney professional to confirm the stack really does have separate flues rather than assume it, since older houses in the region were not built to one pattern.

Power, Air Temperature, and Run Time
A Small Blower Circuit Becomes a Feeder
A gas furnace runs on one 15 amp, 120 volt circuit, and an air handler with a strip heat package needs a 240 volt feeder sized to the heater kit. Homeowners expect this change least, and it is the one that most often turns a mechanical project into an electrical one as well.
Add up what a furnace actually draws. One blower motor, a control board, an inducer motor, and an igniter for a few seconds per cycle. Small. Now look at the amperage on a strip heat package. Ten kilowatts of strip heat on a 240 volt supply pulls a little over 41 amps on its own before the blower load goes on top, which puts the circuit in 60 amp territory with conductors sized to match, and larger kits get split across two circuits through a factory breaker kit mounted inside the air handler cabinet.
The outdoor unit takes its own circuit as well, with a disconnect within sight of the equipment, and that circuit is frequently larger than the one the old air conditioner ran on.
So the panel matters. A house with a 100 amp service, a full breaker panel and an electric range may not have room for a 60 amp feeder without a service evaluation, and the load calculation that settles the question is an electrician's work under the National Electrical Code. Any proposal that never mentions the panel has not looked at it.
Supply Air Arrives Cooler and Stays On Longer
A furnace pushes air into the ducts far hotter than a heat pump does, and a homeowner notices that at the registers long before the thermostat shows anything. Put a thermometer in a supply boot with the furnace running and you will read somewhere around 120 to 140 degrees. Do the same with a heat pump on a mild day and the reading lands closer to 95 to 105, sliding down as the outdoor temperature falls.
Skin sits near 90 degrees. Air at 95 feels like nothing against a forearm, and air at 95 moving past an ankle reads as cool even while it adds heat to the room. That reaction is physiology, and it catches people on the first cold weekend after a conversion.
Run time changes along with it. A furnace fires hard, satisfies the thermostat in 10 or 15 minutes and shuts off, and the house swings a degree and a half either side of the setpoint. Heat pumps hold a lower output for much longer, sometimes running for hours without a break on a cold evening, which is the equipment working correctly rather than struggling to keep up. Room temperature stays flatter and the air feels less dry, and both of those take a few weeks to register with a homeowner as improvements.
Two practical notes come out of this. Registers under a desk or beside a favorite chair deserve a deflector, and a thermostat programmed to drop six degrees overnight will call those expensive electric strips to recover in the morning, so deep setbacks work against a heat pump in a way they never worked against a furnace.
What the Duct System Sees
Ducts on a heat pump move more air for more hours, and a duct system that was sized tight for furnace air will make that known. Heat output follows airflow multiplied by temperature rise. A furnace gets its output from a big rise, so it can heat a house on modest airflow. Heat pumps work with a small rise, which means they need the volume, and the duct design procedure ACCA publishes as Manual D is what sizes a system to deliver it, generally in the range of 350 to 400 cubic feet per minute for every ton of capacity, in heating as well as in cooling.
Undersized returns announce themselves as noise first. One 14 inch return grille trying to feed a three ton air handler whistles, static pressure climbs behind it, and a blower fighting high static moves less air than its label claims at any speed tap.
Measurement answers the question, which is why a Manual J load calculation, the room by room heat loss and heat gain procedure from the Air Conditioning Contractors of America, sizes the equipment, and why static pressure readings taken at the existing furnace before anything is ordered tell an installer most of what the paperwork later confirms.
Scope matters here. TerraStream Energy installs equipment and does not take duct work on, so when the measurements show a return is too small or a trunk is choked, a duct contractor handles that piece and the equipment selection gets made around the airflow the house actually has. Duct repairs, sealing, resizing and replacement all sit with that trade.
How TerraStream Energy Would Approach This
TerraStream Energy converts Maryland homes off gas and oil heat onto electric heat pumps, with Prince George's County as its first market, and this exact swap, one furnace and one air conditioner out and one heat pump system in, is the work the company does most.
A visit starts in the basement with a tape measure and a manometer rather than a tablet. TerraStream Energy runs a Manual J on the house instead of copying the old nameplate, since a furnace installed in 2003 was probably oversized for that house even in 2003. Dimensions of the existing plenum and the return drop get written down. Static pressure gets read across the current blower. Then comes the panel and whatever space is left in it, a count of what else is still on the gas meter, and a careful look at how the water heater vents.
On equipment, TerraStream Energy installs Daikin and Goodman. Both lines come as a matched heat pump and air handler with a factory strip heat kit, and both are listed in the AHRI certification directory, where a homeowner can look up the rated performance of the exact outdoor and indoor combination written on a proposal. The choice between the two on a given house follows the capacity and the cold weather output the load calculation asks for.
New systems ship on R-32 refrigerant, which carries a lower global warming potential than the R-410A in the unit coming out and runs at higher pressure. That pressure is why line set condition and sizing get verified with a gauge set rather than a glance, and why some conversions get fresh copper even when the old tubing looks fine.
Financing runs through the Palmetto Comfort Plan, a lease with no large upfront equipment cost, for a homeowner who would rather not write a check for a whole system at once.
Two items go on the proposal in writing before any equipment gets ordered. One is an orphaned water heater on a shared chimney, which needs a plumber or a chimney contractor. The other is a panel or feeder that cannot carry the strip heat package, and that one needs a licensed electrician looking at it well before an install date gets set. Permits follow the rules of the jurisdiction, and a homeowner can read the Prince George's County permitting office's requirements directly. Incentive programs and federal credit rules change from year to year, so the place to confirm what applies right now is the Maryland Energy Administration's residential program pages along with a tax professional, and no number belongs in a household budget until the program itself confirms the current terms.
A homeowner weighing a like for like swap against a conversion can see what TerraStream Energy does on its heating and cooling page, or call 703-772-5970 and have somebody walk the basement, read the static pressure, and put the measurements on paper.
Frequently Asked Questions
Does one heat pump really do the work of both the furnace and the air conditioner?
Yes, and in cooling it is the same machine an air conditioner already was. The outdoor unit keeps the compressor, the coil and the fan, and a reversing valve lets the refrigerant circuit run backward so the indoor coil becomes the hot one in winter. Indoors, the furnace cabinet is replaced by an air handler that holds the blower, the coil and an electric backup heat package. One thermostat, one outdoor unit, one indoor cabinet. The gas burners, heat exchanger, inducer and flue have no equivalent in the new system because nothing burns.
What happens to my gas water heater if it shared the chimney with the furnace?
It becomes an orphaned appliance and needs attention before the heating season. The furnace used to warm that masonry flue every cycle and carry the water heater's exhaust along with its own. Alone, a small atmospheric water heater cannot reliably drive its own draft up an oversized cold flue, and a weak or reversed draft spills flue gases at the draft hood. The fixes are a correctly sized liner, a power vented or direct vent replacement, or an electric water heater. A plumber or a chimney contractor performs that work, not the HVAC crew.
Will the conversion require electrical work?
Almost always, yes. A gas furnace draws very little, usually one 15 amp 120 volt circuit for the blower and controls. An air handler with a strip heat package needs a 240 volt feeder sized to the heater kit, which puts a 10 kilowatt kit in 60 amp territory, and bigger kits get split across two circuits. The outdoor unit takes its own circuit with a disconnect in sight of the equipment. Whether an existing panel has room for that is a load calculation under the National Electrical Code, and a licensed electrician answers it.
Why does the air from the registers feel cooler than it did with my furnace?
Supply air temperature drops. A furnace commonly delivers air in the 120 to 140 degree range, and a heat pump delivers closer to 95 to 105 on a mild day, lower as it gets colder outside. Skin sits near 90 degrees, so air at 95 reads as neutral or even cool at a register while it is still adding heat to the room. Run times get longer to compensate, which holds room temperature flatter than a furnace did. A deflector on a register near a chair or a desk solves most of the complaint.
Can the installer reuse my existing copper line set?
Sometimes. Copper that is correctly sized for the new equipment, undamaged and running a reasonably short path can be flushed and kept. Tubing that is undersized, kinked, or buried in a wall with no access gets replaced. Systems on R-32 operate at higher pressure than the R-410A coming out, so the existing tubing has to be confirmed as rated for it rather than assumed. That is a gauge set and a spec sheet decision made during the survey, before equipment is ordered.
Who in Maryland does this specific swap?
TerraStream Energy converts Maryland homes off gas and oil heat onto electric heat pumps, with Prince George's County as its first market, and installs Daikin and Goodman equipment on R-32 refrigerant. The company also handles high efficiency whole system replacement. Duct work, plumbing and electrical upgrades belong to those trades, and they get flagged on the proposal rather than quietly absorbed. Call 703-772-5970 to have the basement measured, including static pressure across the existing blower and a look at how the water heater vents.