Converting a Gas Furnace to a Heat Pump in a Maryland Home

Key takeaway: Converting a Maryland house off a gas furnace and a separate air conditioner means one electric heat pump takes over both jobs, and the work that decides whether it succeeds happens before any equipment is ordered. A Manual J load calculation replaces the old furnace nameplate. An electrical load calculation says whether the existing panel and service can carry the new 240 volt load. The gas branch gets capped, and a water heater left sharing the old chimney has to be re-vented or relined. Maryland winter design temperatures sit in the teens, comfortably above the 5 degree Fahrenheit point ENERGY STAR certifies cold climate heat pumps at, so the technology fits this climate when the balance point is calculated and backup heat is sized to the real gap. Dual fuel keeping the gas furnace as backup is a legitimate choice in some houses and a way to avoid the hard work in others. TerraStream Energy converts gas and oil heated homes onto electric heat pumps across Maryland, with Prince George's County first, and will tell you plainly when a house is not a good candidate.
What a Conversion Actually Changes
What a Gas to Heat Pump Conversion Replaces
A real conversion takes out the gas furnace and the outdoor air conditioner and puts one electric heat pump in their place, so a single machine carries both the heating and the cooling load for the whole house.
Today a furnace and an outdoor condenser share one duct system, one blower and one thermostat, which is why a dead furnace in August can also mean no air conditioning. A conversion changes almost all of that. The furnace cabinet comes out and an air handler goes in, a sheet metal box holding the indoor coil, a variable speed blower, and usually an electric heat element for backup. Outside, the condenser is replaced by a heat pump, the same vapor compression machine with a reversing valve added. Flip that valve in winter and the refrigerant circuit runs backward, collecting heat out of cold outdoor air and releasing it into your ducts. The thermostat gets replaced too, because the old one has no way to stage backup heat or lock it out.
TerraStream Energy converts Maryland homes off gas and oil heat onto electric heat pumps, and that electrification work is the center of what the company does rather than a sideline to equipment sales. TerraStream Energy also replaces an aging furnace and air conditioner with a new high efficiency system when the house or the budget points that way instead.
Three choices sit on the table. A like for like swap puts a new furnace and a new air conditioner where the old ones were. A full conversion removes the gas appliance. Dual fuel keeps the furnace and adds a heat pump, which is a real option and also the one most often sold as a conversion when it is not one.
Why Manual J Replaces the Old Nameplate
Sizing a conversion off the old furnace's nameplate is the most common way these jobs go wrong, because that furnace was almost certainly oversized the day it was installed.
Manual J is the residential load calculation standard published by the Air Conditioning Contractors of America and recognized as an ANSI standard. It works room by room. Wall, ceiling, window and door areas with their actual assemblies, orientation, shading, air leakage, duct losses through unconditioned space, internal gains. The output is two numbers your house owns and the equipment has to serve, a heating load at winter design conditions and a cooling load split into sensible and latent. ACCA publishes the technical manuals that define the method, along with Manual S for equipment selection and Manual D for duct sizing.
The nameplate is not evidence. That furnace was probably sized by a rule of thumb and rounded up to the next available model, and in the years since you may have added attic insulation or replaced windows. An oversized gas furnace hides its own mistake. It short cycles, overshoots, and nobody complains because the house gets warm fast. A heat pump does not hide it. Oversize the same house by a third and the unit satisfies the cooling thermostat before it has run long enough to pull moisture out of the air, which is how you end up with a 72 degree house in a Maryland August that still feels clammy. In heating it short cycles through the long shoulder seasons, where most of the annual run hours actually are.
The load calculation also matters more in a conversion than in a swap. Your heating load and your cooling load are different numbers, and in Maryland the heating load is the bigger one in most houses. A furnace and an air conditioner each got sized to their own season. One heat pump serves both, so the selection gets made against the cooling load for comfort and humidity control, then checked against how much of the heating load that same unit covers when it is cold out. The gap is what backup heat exists to fill, and you cannot find the gap without the two numbers.
A real Manual J comes back as a document. Design conditions at the top, a row per room with its load and its required airflow, totals at the bottom. If what you get is a tonnage figure in an email, no calculation happened.

The Work Behind the Walls
The Electrical Side of a Conversion
A conversion adds a new 240 volt load to your house, and whether the existing panel and service can carry it is a calculation an electrician performs, not something anyone should eyeball in your basement.
Consider what leaves and what arrives. The gas furnace ran on one small 120 volt circuit, because all it powered was a blower, an igniter and a control board. In its place you get a heat pump outdoor unit on its own 240 volt circuit, an air handler that may carry an electric backup heat element drawing serious current, and a disconnect at the outdoor unit. That is a meaningful change in a 1960s Hyattsville rancher still running its original panel.
The answer comes from a load calculation under the National Electrical Code, which has a method specifically for existing dwellings taking on additional loads. It frequently shows that a 100 amp service can carry a heat pump when the backup heat is sized honestly, so read the number stamped on your main breaker for context and leave the conclusion to the calculation.
That last point is where homeowners get oversold. A backup heat kit sized to cover the entire design heating load is both the expensive way to run the system and the thing most likely to force a service upgrade. Size the kit to the actual gap above the balance point and the electrical ask shrinks. A dual fuel arrangement with no electric strip heat at all shrinks it further. The Department of Energy's guidance on home upgrades is a reasonable orientation to how electrification and panel capacity interact.
Panel work and service upgrades belong to a licensed electrician, and a service upgrade also involves the utility, since the meter and the service drop are Pepco's equipment in Prince George's County. Get the electrical scope written down. Which circuits, what breaker sizes, and whether a panel change is included in the price or excluded from it.
The Gas Line, the Flue, and the Chimney
Pulling the furnace does not settle the gas question, and the detail that catches most homeowners is the water heater that was quietly sharing the chimney with it.
The gas branch feeding the furnace gets shut off and capped by whoever holds the gas license on the job. Your meter stays as long as anything else in the house burns gas, which usually means a water heater, a range, a dryer or a fireplace. If the furnace was the last gas appliance, you can ask the gas utility to pull the meter and end the fixed monthly charge. That is a phone call you make to the utility.
Now the flue. An older 80 percent AFUE furnace, meaning Annual Fuel Utilization Efficiency, the share of fuel energy it turns into usable heat across a season, vented hot exhaust up a masonry chimney by natural draft. In Maryland houses of that era the gas water heater very commonly vents into that same chimney. The furnace was the big appliance that warmed the flue and got the draft established. Take it out and the water heater is left alone in a tall cold oversized flue, a condition the trades call an orphaned water heater. It may not develop enough draft to vent reliably, which risks condensation inside the chimney, deterioration of the liner and the brick, and spillage of combustion products into the house.
The fix is not complicated and it is not optional. Reline the chimney to a diameter correct for the water heater alone, move the water heater to a different vent arrangement, or replace it with an electric or heat pump water heater and abandon the chimney for good. That work belongs to a chimney specialist or a plumber. A conversion quote should name who is handling it and when, because the inspection at the end will look at how the remaining appliance vents.
One more thing nobody mentions in the sales call. A heat pump runs in winter, and running in winter means it periodically reverses itself to melt frost off the outdoor coil, which produces water underneath the unit on a 30 degree day. Set the outdoor unit on a riser above where ice and snow pile up, and give that defrost water a path away from the pad. Units sitting flat on a slab at grade turn into ice sculptures by February.
What Your Existing Ductwork Decides
The duct system already in your house sets a ceiling on what any heat pump can do there, and that stays true even though duct work sits outside a conversion scope.
Here is the mechanism. A furnace compensates for a mediocre duct system by sending very hot air through it. A heat pump has no such lever. It delivers cooler supply air and makes up the difference with volume and runtime, which means a return path that was merely adequate for a furnace becomes the limiting factor. Undersized returns, crushed flex runs through a hot attic, a filter rack too small for the filter somebody is putting in it. A furnace tolerated all of it. A heat pump shows you, as rooms that never catch up and as a coil operating outside the airflow it was rated at.
The number to ask about is external static pressure, read across the air handler with a manometer. High static means the blower is fighting the duct system, which costs capacity and watts at the same time. Paired with a measured total airflow against the equipment's rated airflow, it tells you whether the duct system can support the machine being proposed. A contractor who measures static before quoting is doing the job. One who discovers it at startup is guessing.
Some of it is fixable inside an equipment replacement. The plenums and transitions at the equipment, the filter rack dimension, and the blower commissioning, since variable speed blowers can be set to a measured airflow rather than left on a factory tap. ACCA's Manual D is the method behind duct sizing.
What is not fixable inside an equipment replacement is the duct system itself. TerraStream Energy does not replace, seal, design or clean ductwork, and the company says so during the survey rather than after the install. If the static pressure reading and the room by room airflow requirement say the ducts cannot carry what the house needs, that work goes to a duct contractor or a home performance specialist, before or alongside the equipment change. Rooms with no duct at all are a different project and belong to a ductless specialist.
Whether It Will Keep the House Warm
How Heat Pumps Behave at Maryland Design Temperatures
Maryland's coldest design conditions sit well above the temperature cold climate heat pumps are certified to perform at, and that margin is the technical reason this technology works here.
Start with the certification, because it is the one claim here that does not depend on anybody's opinion. For a ducted split system to carry the ENERGY STAR cold climate designation it has to reach HSPF2 of 8.1 or better and SEER2 of 15.2 or better, then clear two low temperature tests. It must hold a COP of at least 1.75 at 5 degrees Fahrenheit, and it must still deliver at least 70 percent of its 47 degree heating capacity at that same 5 degrees. Those thresholds are published in the ENERGY STAR key product criteria. COP is coefficient of performance, heat delivered divided by electricity consumed, so a COP of 1.75 means the machine is still moving 1.75 units of heat for every unit of electricity it draws at 5 degrees. ENERGY STAR notes that an air source heat pump can deliver up to three times more heat energy to a home than the electrical energy it consumes.
Design temperature is the other half of the comparison. It is the outdoor temperature a system gets sized against, drawn from the climatic design data ASHRAE maintains in its weather data center, chosen so that it is colder than all but roughly one percent of winter hours. For Prince George's County and the counties around it that figure lands in the teens. Not below zero. The certified 5 degree test point sits below your design condition with room to spare, which is a different situation from Minnesota and a different conversation than the one homeowners heard about heat pumps fifteen years ago.
Every heat pump does make less heat as the air gets colder. That is physics, not a defect. The number that matters is the unit's rated heating capacity at your design temperature, which lives in the manufacturer's extended performance tables rather than on the box. Inverter driven variable capacity compressors hold their capacity down the temperature curve far better than the single stage units that gave heat pumps their reputation.
Expect the system to feel different. A furnace delivers a short blast of distinctly hot air and shuts off. A heat pump delivers air that feels merely warm and runs for hours. Rooms end up more even and the house gets quieter, but a homeowner standing at a register expecting furnace air will think something is broken.
Balance Point and the Backup Heat Decision
Balance point is the outdoor temperature at which your house's heat loss equals what the heat pump can deliver, and it is the single number that decides how much backup heat you actually need to install.
Picture two lines. One is your house's heat loss, rising steadily as it gets colder outside, taken straight off the Manual J. The other is the heat pump's output, falling as it gets colder, taken off the manufacturer's extended data for that exact model. Where they cross is the balance point. Above it the heat pump carries the house by itself. Below it something makes up the shortfall. A conversion selected properly in Maryland puts that crossing point well below the design temperature, so backup heat covers a small number of winter hours instead of carrying the house all season.
Two backup options exist. Electric resistance elements in the air handler, cheap to install and expensive to run. Or the gas furnace you already own, kept in place as a dual fuel arrangement. Which one makes sense depends on the panel, the house, and your reason for converting in the first place.
Controls matter more than the hardware here, and this is where good installs separate from bad ones. Strip heat should be locked out above a set outdoor temperature so the thermostat physically cannot bring it on just because the setpoint moved. A multi stage kit brings elements on one at a time instead of all at once. The thermostat's recovery logic has to be configured for a heat pump, not left on whatever default shipped in the box.
One habit has to go with the furnace. Deep nighttime setbacks worked fine with a machine that could blast the house back up quickly. With a heat pump, recovery from a big setback is precisely when a thermostat decides it needs emergency heat, and the setback savings come back out in strip heat. Set it and leave it, or use a thermostat with intelligent recovery that ramps the compressor early.
Dual Fuel as a Choice and as a Crutch
Dual fuel, where the heat pump runs most of the season and the existing gas furnace takes over below a set outdoor temperature, is the right answer in a specific set of houses and a hedge against bad sizing in all the rest.
The arrangement is simple. One thermostat, an outdoor sensor, a switchover setting. Below it the compressor stops and the furnace runs, and the two never operate at once. It earns its place in real situations. Your furnace is young and the air conditioner is the dead one, so you are buying an outdoor unit anyway. The load calculation says a strip heat kit forces a service upgrade you do not want to fund. The house has a high heat loss, which describes a fair number of the 1950s and 1960s houses in Bowie, Clinton and Hyattsville that still have modest wall insulation. In all of those, dual fuel is the honest engineering answer.
It becomes a crutch when it is used to avoid work. A homeowner says they want off gas, and the quote comes back keeping a twenty year old furnace in service as the backup. That furnace is now the oldest and most failure prone component in a brand new system. The gas meter stays with its fixed monthly charge. The chimney and flue questions never get answered, and in a few years you are buying the furnace anyway. Dual fuel can be a smart purchase. It is not getting off gas, and a quote that presents it as a conversion is telling you something about the contractor.
"When somebody tells me they want off gas, the first thing I do is pull the panel cover and walk the duct system, not open an equipment catalog. The load calculation and the electrical picture decide what is actually possible in that house. If dual fuel is the honest answer for a house I will say so, and if the ducts will not carry the air I will say that too, because a system the house cannot support is not a win for anybody." Jake Mazzoccoli, Owner, TerraStream Energy
What you are comparing | Like for like swap | Full heat pump conversion | Dual fuel |
|---|---|---|---|
What gets replaced | New gas furnace, new air conditioner, same configuration | Furnace and condenser both removed, heat pump and air handler installed | Condenser replaced with a heat pump, existing furnace stays as backup |
How it should be sized | Manual J, though the nameplate often gets copied instead | Manual J plus capacity at design temperature plus a calculated balance point | Manual J for cooling, plus a switchover temperature set against the furnace capacity |
Electrical work involved | Minimal, the furnace circuit is reused | New 240 volt circuits, backup heat kit, load calculation, sometimes a service upgrade | New 240 volt circuit for the heat pump, no strip heat load added |
Gas line and flue | Unchanged, same venting and same combustion air | Branch capped, flue abandoned, orphaned water heater has to be addressed | Unchanged, furnace keeps venting and the chimney questions stay open |
Behavior in a Maryland cold snap | Furnace output is flat regardless of outdoor temperature | Capacity falls as it gets colder, backup heat covers below the balance point | Furnace takes the coldest hours entirely, heat pump idles |
Sensitivity to existing ducts | Low, high supply air temperature masks marginal airflow | High, lower supply temperature means airflow and static pressure have to be right | Moderate, the furnace covers the hours when airflow matters most |
Who still pays a gas bill | You do, including the fixed monthly charge | Only if another gas appliance remains in the house | You do, for as long as the furnace stays |
Three ways to replace an aging gas furnace and air conditioner in a Maryland single family home

Running Cost, Permits and Paperwork
SEER2, HSPF2, and the Operating Cost Question
SEER2 and HSPF2 describe how efficiently equipment uses electricity, and neither one can be set against a furnace's AFUE on a calculator, which is why a gas to heat pump operating cost comparison has to be worked out on your own utility rates.
SEER2 is the Seasonal Energy Efficiency Ratio 2, cooling output in BTU divided by electricity input in watt hours across a representative cooling season. The 2 matters. The current test procedure uses higher external static pressure than the old SEER test, so the same physical machine rates lower in SEER2 than it did in SEER, and a homeowner comparing a 2016 quote to a 2026 quote will think efficiency went backward. It did not. The ruler changed.
HSPF2 is the Heating Seasonal Performance Factor 2, the same arithmetic for the heating season. AFUE is a different animal, a percentage of fuel energy a furnace converts to heat, which cannot exceed 100. A heat pump running at a COP of 3 is not 300 percent efficient. It is moving heat that already exists outdoors instead of creating heat by burning something.
Which brings us to the honest answer on bills. To compare gas heating against heat pump heating in your house you need your all in electric rate per kilowatt hour and your all in gas rate per therm, delivery and fixed monthly charges included, run against the heating load from your Manual J and the unit's COP across the temperature bins your climate actually produces. That is house specific arithmetic, which is exactly why no honest contractor hands you a savings figure off a brochure. Pull your own bills, and the Maryland state energy profile from the Energy Information Administration is a reasonable place to see how the state's residential rates have been moving.
Worth saying plainly that ENERGY STAR frames heat pump savings most strongly against electric resistance, propane and oil heat. Against natural gas in Maryland the arithmetic is tighter, and most homeowners who convert anyway have reasons beyond the monthly bill. One system instead of two. No combustion appliance and no flue inside the house. A heating load that can eventually move onto their own roof.
Incentives can change the picture and they change on their own schedule. Federal credit rules and state program terms get rewritten, funded, and exhausted. Look at the Maryland Energy Administration's list of grants, loans, rebates and other incentives and at the ENERGY STAR page on federal tax credits for air source heat pumps, then confirm current terms with those authorities and your own tax professional before you build a number into your budget. Nobody should promise you an incentive outcome, and a contractor who does is making a promise they do not control.
Permits, Inspection, and What to Get in Writing
A heat pump conversion in Prince George's County requires a mechanical permit pulled by a Maryland licensed contractor and an inspection at the end, and a quote that mentions neither one is telling you how the job will go.
The county's Department of Permitting, Inspections and Enforcement requires a mechanical permit to install, alter, replace, remove or convert a heating, ventilating or air conditioning system. The applicant has to hold an HVAC contractor's license, the installation gets inspected by a county building inspector, and a single family application includes an HVAC System Certification Form signed by a mechanical contractor licensed in the state of Maryland.
A conversion usually touches more than one trade and therefore more than one permit. The mechanical work is one. New electrical circuits or a panel change is an electrical permit under a licensed electrician. Capping the gas branch is its own trade. Ask who pulls which permit and get the answer written into the proposal, along with who schedules the inspections.
TerraStream Energy works across Maryland and takes Prince George's County first, where the permitting and install history sits.
Now the part to print out. A conversion proposal worth signing contains all of this.
Full model numbers for the outdoor unit, the indoor air handler or coil, and the thermostat. Not "3 ton heat pump, high efficiency."
The AHRI certified reference number for that matched combination. A published rating belongs to a specific outdoor and indoor pairing, not to the outdoor unit alone. AHRI's directory of certified products lets you check it yourself.
The Manual J report, with the design conditions it used and the room by room loads, not a summary sentence claiming one was done.
The unit's rated heating capacity at your design temperature, from the manufacturer's extended performance data, and the balance point calculated from it.
The size of the electric backup heat kit in kilowatts and how it is locked out, or for dual fuel, the switchover temperature and what it was set against.
Electrical scope in detail. Circuits, breaker sizes, disconnect, and whether a panel or service upgrade is included or excluded.
Gas and flue scope. Who caps the line, what happens to an orphaned water heater, who relines or abandons the chimney.
Commissioning deliverables. Measured external static pressure, measured airflow, charge verified by weight with superheat and subcooling recorded, and a copy handed to you.
Spotting a furnace swap with a heat pump sticker on it gets easy once you know the tells. No Manual J. Tonnage matching the old nameplate exactly. A backup heat kit sized to the full design load, which means nobody calculated a balance point. No capacity at design temperature anywhere in the paperwork. No static pressure reading. No AHRI number. No permit named. And the biggest one, a proposal that says heat pump, keeps your furnace, and never uses the words dual fuel.
How TerraStream Energy Would Approach This
The sequence is survey, then calculate, then select, then write it down, and no equipment gets named until the first two are finished.
The survey is a walk through the whole house, not a look at the furnace. Panel cover off to read the main breaker and count spaces. How the furnace vents and, right behind it, how the water heater vents. Static pressure read across the existing air handler. Room by room measurements for the load calculation. Where an outdoor unit can sit with clearance, a riser, and a path for defrost water.
The Manual J comes next, and the equipment selection follows from it rather than the other way around. TerraStream Energy runs the load calculation on a conversion instead of carrying the old nameplate forward, then checks the selected unit's capacity at the Maryland design temperature, states the balance point, and sizes the backup from that gap. If the honest answer for a particular house is dual fuel, or a straight replacement of the furnace and air conditioner rather than a conversion, that is what gets proposed.
TerraStream Energy installs Daikin and Goodman equipment. Both lines offer inverter driven variable capacity heat pumps with published extended performance data down into low outdoor temperatures, which is the data a balance point calculation requires. Narrowing to two manufacturers is deliberate. Installers who set the same equipment repeatedly commission it correctly, and parts availability for a system you will own for many years matters more than a spec sheet advantage.
New systems go in on R-32 refrigerant. The reason is regulatory. EPA's technology transitions program sets limits on the use of high global warming potential hydrofluorocarbons in air conditioning and heat pump equipment, which is why the industry moved off R-410A for new residential equipment. R-32 has a substantially lower global warming potential and is classified A2L, mildly flammable, which brings installation and service practices technicians train for. A system installed today on R-32 has a refrigerant supply path ahead of it. A new R-410A system does not.
What you should expect to receive is paper. Model numbers, the AHRI match, the load calculation, the capacity at design temperature, the balance point, the backup strategy, the electrical scope, who handles the gas line and the water heater venting, and commissioning readings taken at startup. TerraStream Energy puts that in the proposal rather than describing it in a conversation.
If you are weighing a like for like swap against getting off gas in Prince George's County or anywhere in Maryland, call TerraStream Energy at 703-772-5970 or get in touch here to start with the survey and the load calculation. Financing is available through the Palmetto Comfort Plan, a lease option that avoids a large upfront equipment cost.
Frequently Asked Questions
Will a heat pump actually keep my Maryland house warm in January?
Yes, when it is sized and selected against your house rather than against the old furnace nameplate. ENERGY STAR's cold climate designation requires a ducted split heat pump to hold a coefficient of performance of at least 1.75 at 5 degrees Fahrenheit and to still deliver at least 70 percent of its 47 degree heating capacity at that temperature. Winter design temperatures for Prince George's County and the counties around it sit in the teens, which is above that 5 degree test point, so a properly selected cold climate unit has margin here. The part that determines whether your particular house is comfortable is the balance point calculation and whether the backup heat is staged and locked out correctly.
Do I have to upgrade my electrical panel to convert to a heat pump?
Not always, and the way to find out is a load calculation under the National Electrical Code rather than a glance at the panel. A conversion adds a 240 volt circuit for the heat pump and, usually, a circuit for an electric backup heat element. How big that backup element needs to be depends on the balance point, and a kit sized to the real gap above the balance point rather than to the whole design heating load is frequently the difference between needing a service upgrade and not. A dual fuel setup with no strip heat at all reduces the electrical ask further. Panel and service work belongs to a licensed electrician, and a service upgrade also involves Pepco, since the meter and the service drop are utility equipment.
What happens to my gas water heater if the furnace comes out?
If the water heater vents into the same masonry chimney the furnace used, it becomes what the trades call an orphaned water heater. The furnace was the appliance that warmed the flue and established draft, and a water heater left alone in a tall cold oversized flue may not vent reliably, which risks condensation inside the chimney and spillage of combustion products into the house. The fix is relining the chimney to a diameter correct for the water heater alone, re-venting it, or replacing it with an electric or heat pump water heater and abandoning the chimney. A chimney specialist or a plumber does that work, and a conversion proposal should name who is handling it rather than leaving it unsaid.
Is dual fuel the same thing as converting to a heat pump?
No. Dual fuel means a heat pump carries the house above a set outdoor temperature and the existing gas furnace takes over below it, so the gas appliance, the gas meter and the flue all stay. That is a legitimate choice when the furnace is young and in good condition, when the electrical load calculation says a strip heat kit forces a service upgrade, or when the duct system cannot carry the airflow a full heat pump wants. It becomes a problem when it is sold as a conversion to a homeowner whose stated goal was getting off gas, especially when the furnace being kept as backup is already twenty years old. Ask the contractor to use the words dual fuel in the proposal if that is what is being proposed.
Will my heating bill go down if I switch from gas to a heat pump?
That depends on your own rates and nobody should answer it from a brochure. ENERGY STAR frames heat pump savings most strongly against electric resistance, propane and oil heat. Against natural gas the arithmetic is tighter and turns on your all in electric rate per kilowatt hour, your all in gas rate per therm including fixed monthly charges, your heating load, and the unit's coefficient of performance across the temperatures your winter actually produces. Note also that you only stop paying the gas fixed monthly charge if the meter comes out, and that only happens when nothing else in the house burns gas. Many homeowners who convert do it for reasons beyond the bill, including removing a combustion appliance from the house and running one system instead of two.
Do I need a permit to replace a furnace with a heat pump in Prince George's County?
Yes. The county's Department of Permitting, Inspections and Enforcement requires a mechanical permit to install, alter, replace, remove or convert a heating, ventilating or air conditioning system, and that covers both furnaces and heat pumps. Applications are submitted online and the applicant has to hold an HVAC contractor's license. A single family permit application includes an HVAC System Certification Form signed by a mechanical contractor licensed in the state of Maryland, and the installation gets inspected by a county building inspector. New electrical circuits or a panel change carry a separate electrical permit under a licensed electrician. Ask who pulls which permit and get it in writing.