The AC Died and the Furnace Still Runs, Three Options in Maryland
Updated: Oct 25

Key takeaway: A heat pump and an air conditioner of the same capacity sit on the same pad, tie into the same two copper lines and land on the same coil position above the furnace, so a failed air conditioner over a working furnace is one decision about what that outdoor machine gets asked to do in January. Three outcomes are genuinely available. A matched cooling only replacement, now constrained by the newer refrigerant generation and by certified coil pairing, which leaves heating exactly as it is. A heat pump over the existing furnace, where a reversing valve wire, an outdoor temperature reading and an installer set switchover point make the furnace the backup heat and leave the flue untouched. Or a full replacement, where the furnace goes, an air handler with electric backup heat takes its place, and a gas water heater left orphaned in the old flue becomes a question for a plumber. Furnace age, heat exchanger condition and whether the existing venting arrangement survives are what decide between the three. TerraStream Energy converts Maryland houses off gas heat onto electric heat pumps and replaces whole heating and cooling systems, Prince George's County first, and settles that question during the site visit rather than over the phone.
Two Boxes That Look Identical
A Heat Pump Sits Where the Air Conditioner Sat
A heat pump sized to match your dead air conditioner bolts to the same pad, ties into the same two copper lines, and lands in the same spot above the furnace. Walk around to the side of the house and look at what is actually there. A box on a plastic or concrete pad. Above it, a gray disconnect box screwed to the siding, with a short flexible conduit whip running down into the cabinet. Two copper lines leave the other side and disappear through the rim joist, one thin and bare, the other fatter and wrapped in black foam.
Follow those lines into the basement. They end at a sheet metal box sitting directly on top of the furnace, and inside that box is an A shaped slab of aluminum fins with a plastic drain pan under it and a small PVC line running off to a floor drain or a pump.
Now picture the heat pump version of that same house. Same pad, same disconnect, same two copper lines through the same hole in the joist. A sheet metal box sits on top of the furnace in exactly the spot the old one held.
Homeowners brace for a demolition project when they hear the word conversion. Outside, the work is close to identical, and the truck that pulls up carries the same copper, the same nitrogen bottle and the same vacuum pump.
What Is Different Inside the Cabinet
The hardware that separates a heat pump from an air conditioner amounts to a four port valve, a few sensors and a control board, all of it inside the outdoor cabinet. Its brass body is about the size of a fist, with four copper stubs brazed into it and a small electric solenoid clamped on top. Send power to that solenoid and an internal slide shifts, which swaps the jobs of the two coils. The outdoor coil starts pulling heat out of cold air, and the coil above your furnace starts dumping that heat into the air headed down the ducts. Plainer language on that same reversal sits in the Department of Energy's guide to heat pump systems.
Several smaller parts ride along with that valve. One is a suction line accumulator, a tall cylinder that catches liquid refrigerant coming back from a cold outdoor coil before it can reach the compressor. Another is a filter drier built to flow in both directions, and a third is a defrost board with a temperature sensor clipped to a bend in the outdoor coil. Crankcase heat for the compressor oil shows up as well, along with a heater in the base pan on many units.
Frost is the part worth understanding, since it looks alarming the first winter. When the outdoor coil runs below freezing in damp air, frost grows on the fins and blocks airflow. The board responds by reversing that valve for a few minutes and shutting the outdoor fan off, so hot gas floods the coil and melts the ice. Steam rolls off the cabinet. Neighbors have called the fire department over it.
One physical difference does show up in the side yard. Heat pump cabinets tend to stand taller than a cooling only unit of the same capacity, because the outdoor coil has to breathe winter air, and the base needs to sit high enough on a riser or bracket that melt water drains away instead of freezing under the unit.
What You Are Actually Choosing
All three of your options put a box on that pad to cool the house in July, so the real decision is about what that box gets asked to do in January. Cooling is settled either way. Heating is the fork.
Two pieces of vocabulary help here. COP, the coefficient of performance, is the heat a machine delivers divided by the electricity it consumes, measured at a stated outdoor temperature. A furnace burns fuel to create heat, while a heat pump moves heat that already exists in outdoor air, which is why its COP comes out above one and why its output falls as the air outside gets colder. SEER2 and HSPF2 are the seasonal cooling and heating ratings the federal test procedure produces for that equipment, and both numbers come from a laboratory test of one outdoor unit paired with one specific indoor coil rather than from the outdoor box on its own.
Answer the January question and the rest of the job falls out of it. Thermostat wiring, whether the furnace stays, whether the flue stays, and whether an electrician gets involved all follow from that single answer.

Option One, The Like for Like Air Conditioner
What Gets Replaced and What Stays
A like for like swap takes out the outdoor unit and the indoor coil, leaves the furnace and the duct work untouched, and asks nothing new of the thermostat.
What leaves the property is a short list. The condenser on the pad, the evaporator coil in its cabinet on the furnace, the old filter drier, and frequently the pad and the aging disconnect whip along with them. What stays is everything else. Burners, heat exchanger, blower, flue, gas piping, every duct in the house, and the five wires already sitting behind the thermostat.
Those wires matter for the comparison later, so here they are. R carries 24 volt power and C completes that circuit, G calls the blower, Y calls the compressor contactor outside, and W calls the furnace. A cooling only replacement reuses all five exactly as they sit.
The line set is the one judgment call in the basement. Existing copper can sometimes stay if the diameters suit the new equipment and the installation instructions allow it, which means a flush, a fresh drier and a pressure test before any new charge goes in. New refrigerants carry an A2L flammability classification under the ASHRAE designation standard, described in ASHRAE's standards resources, and that classification brings install details of its own, including leak detection built into indoor equipment. Older copper that was buried in a wall and cannot be pressure tested properly gets replaced.
Refrigerant Generation and Coil Matching
The squeeze on a like for like replacement is that new residential outdoor units no longer ship with the refrigerant your old coil was built and certified around. Equipment installed through the early 2020s runs on R-410A. New residential split systems arrive on lower global warming potential refrigerants instead, R-32 and R-454B among them, under the hydrofluorocarbon phasedown and the EPA technology transitions program.
Ratings follow pairs, never boxes. The Air Conditioning, Heating and Refrigeration Institute runs the third party certification program that publishes a reference number for each tested combination of outdoor unit and indoor coil. No certified combination exists that marries a new lower global warming potential outdoor unit to an R-410A era coil, since the refrigerant, the oil and the metering device are all different. The coil comes out whether or not it looks fine.
So the narrow version of this option, keeping the indoor coil and changing only the box outside, has mostly closed. A separate piece on this site walks through the few houses where it still works. For everyone else a like for like swap means a new matched pair, and the moment a coil is coming off that furnace anyway, the furnace underneath it earns a hard look in the same visit.
How the House Behaves Afterward
Cooling comes back the way you remember it and heating does not change at all, which is the entire appeal of this route. Same whoosh when the furnace lights, same hot supply air in February, same shape to the gas bill. Nothing new to learn at the wall.
One thing does shift, and it is a calendar problem rather than a comfort problem. A new air conditioner starts a fresh service life on top of a furnace already two decades into its own, which puts the next failure on the heating side and puts the brand new coil directly in the way of that repair. Labor overlaps. A crew pulling a dead furnace out from under a two year old coil has to disturb the coil, break the refrigerant connections and recharge the system to finish a job that had nothing to do with cooling.
Homeowners who choose this route with their eyes open usually have a reason. Maybe the furnace is only three years old. Or a roof is already eating the money this year, and the house goes on the market before the next heating season anyway.
Option Two, A Heat Pump Over the Existing Furnace
What a Dual Fuel System Physically Is
Dual fuel means one house with two heat sources under one control, an electric heat pump outside and the gas furnace you already own inside, with the control picking between them based on outdoor temperature. Installers also call it a hybrid system.
Physically, almost nothing new appears in the basement. A heat pump goes on the pad. Its matched indoor coil goes into a cabinet on the furnace supply plenum, the same position the old evaporator coil held. The furnace blower stays as the air mover for both machines, which is why this arrangement needs no electric backup heat elements at all. Backup heat is the furnace itself.
Coil position carries a consequence most homeowners never hear about. In a standard upflow furnace the coil sits downstream of the heat exchanger, so when the furnace fires, its hot air passes through that coil on the way to the ducts. Coils are built to take it. The control, though, has to keep the two machines from running at the same moment, since furnace air blowing across an operating coil drives refrigerant pressure up and trips the compressor on its high pressure switch.
TerraStream Energy installs this arrangement as the middle path for a Maryland house with a sound furnace, since it converts the mild two thirds of the heating season to electricity without touching the flue, the gas piping or the service panel. That house keeps gas heat for cold snaps and gains a heat pump for everything above them.
What the Switchover Control Does and Who Sets It
The switchover is a decision the thermostat makes from an outdoor temperature reading, and the temperature it switches at gets set by the installer during commissioning.
Start with the wiring, since dual fuel stops resembling an air conditioner right at the thermostat. A sixth wire has to reach the outdoor unit, usually labeled O or B, and it energizes the reversing valve solenoid so the system knows to run backward. Y still calls the compressor and W still calls the furnace. The system also needs an outdoor air temperature reading, either from a small puck mounted in shade on a north wall and wired back to the thermostat, or from the equipment's own control.
Balance point is the term those rules are built around. It is the outdoor temperature at which the heat pump's output exactly equals the rate the house loses heat. Above it, the heat pump holds the house alone. Below it, something has to make up the shortfall. Finding that temperature takes a room by room heat loss calculation against the local winter design condition, the procedure the industry knows as Manual J and publishes through ACCA's technical manuals, read against the manufacturer's capacity tables for the chosen heat pump at each outdoor temperature.
From there the installer programs three behaviors. A compressor lockout, below which the heat pump stays off and the furnace handles heating by itself. Then a furnace lockout, above which the furnace stays off no matter what the thermostat asks for. Last, an interlock that forbids both at once. Some controls also allow the furnace to temper the air during a defrost cycle, so the registers do not blow cool air while the outdoor coil melts.
Nobody should be guessing at those numbers in a phone app. The installer sets them in the thermostat's installer menu, writes them on the commissioning sheet, and leaves that sheet with the homeowner. Switchover temperature is fair game to revisit after one winter, since relative fuel prices move and the natural gas price data EIA publishes in March rarely matches the assumption somebody made in October.
How the House Behaves Afterward
The system runs longer and quieter through most of a Maryland winter, with the furnace firing only during the cold stretches.
Run times stretch out. A furnace delivers heat in short hot bursts and then shuts off, while a heat pump settles into long steady cycles that hold a room closer to its setpoint. Air at the register feels cooler to the back of a hand even while the thermostat reads exactly what it always read, because supply temperature on a heat pump sits closer to skin temperature than furnace air does. That one sensation accounts for most of the complaints heat pumps collect in their first season, and a good installer explains it before the first cold night rather than after.
Deep thermostat setbacks lose their appeal. Dropping the house eight degrees overnight means the morning recovery outruns the heat pump and pulls in the furnace, which gives back the savings the setback was supposed to buy. Steady setpoints suit this equipment.
Outside, the unit runs when it is cold, which surprises people whose condenser sat silent every winter. The machine hums under its fan. Frost grows on that outdoor coil through a damp January night and the defrost cycle melts it off in a cloud of steam. The gas meter still turns on the coldest mornings, and a gas water heater keeps its own load no matter what happens with the heating.
Incentive programs attach to some of this work and their rules change from year to year, so confirm current terms with the Maryland Energy Administration's residential incentive listings and with the federal tax credit pages ENERGY STAR maintains before any number goes into a budget.

Option Three, Everything Goes, and the Furnace Question
What Comes Out and What Goes In
A full replacement pulls the furnace out along with everything else and puts an air handler in its place, which is a cabinet holding a blower and a coil and no combustion of any kind.
The removal list grows. Furnace, coil, condenser, the gas connection capped at the appliance shutoff valve, and the flue pipe taken off the chimney or out of the sidewall. What goes back in is an air handler matched to the duct system, the coil for the new heat pump inside it, electric resistance elements in the cabinet as backup heat, fresh sheet metal transitions top and bottom to meet the existing plenums, and a condensate path that now has to work year round rather than in cooling season alone.
An air handler brings one quiet gain in a tight mechanical closet, since it has no draft hood, no flue and no combustion air openings, which stops the space around it being governed by what a burner needs to breathe.
The electric side becomes real in this option, since backup heat elements draw serious current and the existing panel may or may not have room for the circuit they need. That question belongs with the electrician on the job, who answers it by pulling the panel cover off and counting what is in there.
Duct work is a subject of its own. A heat pump moves more air at a lower temperature than a furnace does, so static pressure in the duct system gets measured before equipment is selected, and if the ducts turn out to be the limitation, that correction is work for a contractor who specializes in it.
Age and the Heat Exchanger
A furnace that stays on as backup heat has to be mechanically sound, which makes its age and the condition of its heat exchanger the two facts that settle this whole decision.
AFUE is the measure to know. Annual fuel utilization efficiency describes the share of the fuel's energy that ends up as heat inside the house across a heating season. A twenty year old atmospheric furnace with a standing draft hood usually lands near eighty percent, while a sealed combustion condensing furnace that drains water out of its own exhaust lands in the nineties, a split the Energy Department lays out on its furnaces and boilers page.
That heat exchanger is the steel wall between combustion gases and the air your family breathes, and it fails in predictable places. Cracks open at the tight radius bends where metal has expanded and contracted through tens of thousands of cycles. Rust eats it from above when a coil drain pan has been leaking onto it for years, which happens more than homeowners expect given that a coil sits right on top of it. Holes appear near the burner ports where flame impingement has thinned the steel.
Confirmation comes from a camera on a flexible wand, from watching the flame pattern distort the moment the blower starts, and from a combustion analyzer reading carbon monoxide in the flue and in the room. A condemned heat exchanger ends the conversation about keeping the furnace. The choice then narrows to a full replacement or a cooling only swap plus a new furnace, and the first of those usually costs less than the second, since it is one visit and one set of connections.
Diagnosing and condemning a heat exchanger is service work. The heating contractor who maintains your furnace is the right party to put that finding in writing, and a replacement company should be reading their report rather than issuing one of its own.
Whether the Existing Venting Survives
Taking the furnace out changes the venting, and if a gas water heater shares that flue, the water heater becomes the problem to solve before any equipment gets ordered.
Two arrangements turn up in Maryland basements. One pairs an eighty percent furnace and a gas water heater, both venting into a masonry chimney or a common B vent through the roof. That flue was sized for the combined output of two appliances. Remove the furnace and the water heater sits orphaned in a chimney far too large for it, with nothing to warm the flue on a cold morning. Draft goes weak. Moisture condenses on cold masonry, and combustion gases can spill out of the draft hood into the room instead of going up.
The fix is a correctly sized liner for the water heater, or a water heater that vents on its own, and verification comes from a spillage test at the draft hood with a carbon monoxide measurement taken in the room. Both are plumbing and venting work for a licensed plumber or your own heating contractor. TerraStream Energy will flag an orphaned flue during the site visit and will say plainly that the liner belongs to somebody else, because inventing that capability would leave a homeowner holding a half finished job.
The second arrangement is simpler, a condensing furnace with white PVC intake and exhaust pipes out through a sidewall, venting nothing but itself. Pull it and two wall penetrations get capped, with no effect on any other appliance.
Keeping the furnace as dual fuel backup sidesteps all of this. Nothing changes in that chimney, the water heater keeps its partner, and the venting question never opens. County permitting treats these paths differently too, and the Prince George's County permitting and inspections office publishes the mechanical permit and inspection requirements for work of this kind.
The Three Options Side by Side
The three options part company at four places in the house, the thermostat, the furnace, the flue and the service panel. Everything out on the pad and in the line set is common ground.
Part of the house | Like for like air conditioner | Heat pump over the furnace | Full system replacement |
|---|---|---|---|
Outdoor unit | New cooling only condenser on the same pad | New heat pump on the same pad | New heat pump on the same pad |
Indoor coil or air handler | New matched coil in the cabinet on the furnace | New matched coil rated for heat pump duty | Furnace replaced by an air handler with electric backup heat |
Furnace | Stays, unchanged | Stays as backup heat below the switchover temperature | Removed, gas capped at the appliance |
Thermostat and control wiring | Existing five wires reused | Reversing valve wire added, outdoor sensor added, lockouts programmed | Reversing valve wire added, backup heat staged by the air handler control |
Flue and water heater | Untouched | Untouched | Flue removed, an orphaned water heater needs its own venting solution |
Winter behavior | Identical to today | Long heat pump cycles above the switchover point, furnace below it | Heat pump year round with electric backup in the coldest hours |
What decides against it | A furnace near the end of its life sitting under a brand new coil | A cracked heat exchanger or a furnace already past service life | A sound young furnace, or a panel with no room for backup heat |
What each option replaces, keeps and changes when the air conditioner has failed and the furnace still runs
How TerraStream Energy Would Approach This
TerraStream Energy treats a failed air conditioner over a working furnace as one decision with three outcomes, and the site visit exists to settle which of the three a house supports.
Every visit runs in the same order. Pad and clearances first, then the line set penetration and whether the existing copper can be pressure tested and reused, then the coil cabinet and how it meets the plenum. Next comes the furnace data plate with its manufacture date, its AFUE and its vent arrangement, followed by the flue itself and the question of whether a water heater shares it. Then the service panel gets opened. Static pressure in the duct system gets measured and reported, with any limitation named out loud rather than papered over. For sizing, TerraStream Energy runs a room by room load calculation against the Maryland winter design condition, never the tonnage painted on the box being hauled away.
Whole system replacement is the other half of what TerraStream Energy does, for the house where the furnace is as old as the air conditioner that just quit and both machines should leave together. The company installs Daikin and Goodman equipment on R-32 refrigerant, and the matched combination with its certified rating goes on the proposal so a homeowner can look the numbers up instead of taking them on faith.
"Half the people who call me after an air conditioner dies assume switching to a heat pump means tearing the basement apart. It does not. The box outside goes on the same pad, on the same two lines, and then we decide together whether your furnace stays in the picture as backup or leaves with the old condenser. That one answer is the whole job." Jake Mazzoccoli, Owner, TerraStream Energy
Some work falls outside what this company does, and saying so early saves everybody a wasted appointment. TerraStream Energy does not run service calls, diagnostics or repairs, does not sell maintenance agreements, does not do duct replacement or duct sealing, and does not install ductless equipment. A cracked heat exchanger gets diagnosed by your service contractor. An orphaned water heater flue gets lined by a plumber.
Across Maryland, with Prince George's County taken first, TerraStream Energy works on single family houses. Replacement and conversion details sit on the heating and cooling page, and a homeowner staring at a dead condenser and a furnace of uncertain age can call 703-772-5970 to have the pad, the flue and the heat exchanger looked at in one visit.
Frequently Asked Questions
Can a heat pump go on the same pad the old air conditioner sat on?
Yes, in most cases. A heat pump of the same cooling capacity uses the same pad footprint, the same electrical disconnect location and the same pair of refrigerant lines through the rim joist. Two practical checks come up. Heat pump cabinets often stand taller, so overhead clearance and the distance to the wall get verified, and the base is set high enough on a riser or bracket that defrost melt water drains away rather than freezing under the unit. The existing copper gets pressure tested and flushed, or replaced if it cannot be tested properly.
Does the furnace have to come out to get a heat pump?
No. A heat pump can run on top of an existing gas furnace as a dual fuel system, which keeps the furnace as backup heat below a set outdoor temperature. That path leaves the flue, the gas piping and the service panel alone, and it needs no electric backup heat elements because the furnace fills that role. The furnace does have to be mechanically sound to stay, which means an intact heat exchanger and enough remaining service life to justify keeping it in the system.
Who decides the temperature where the furnace takes over?
The installer sets it during commissioning, in the thermostat's installer menu, and records it on the commissioning sheet. The setting comes from the balance point, the outdoor temperature at which the heat pump's output equals the rate the house loses heat. Finding it takes a room by room heat loss calculation and the manufacturer's capacity tables for the selected heat pump at each outdoor temperature. A homeowner can ask for that number to be revisited after one winter, since fuel prices and comfort preferences both move.
The indoor coil looks fine. Can it stay?
Rarely now. New residential outdoor units ship on lower global warming potential refrigerants such as R-32 and R-454B, while coils installed through the early 2020s were built and certified for R-410A. Published capacity and efficiency belong to a certified pairing of outdoor unit and indoor coil, and no certified pairing exists that joins a new outdoor unit to an older coil, since the refrigerant, the oil and the metering device differ. A coil in good condition still comes out, and that is the moment to look at the furnace under it.
What happens to a gas water heater when the furnace comes out?
If both appliances vent into one chimney or a shared B vent, removing the furnace leaves the water heater orphaned in a flue sized for two appliances. Draft weakens, moisture condenses on cold masonry, and combustion gases can spill at the draft hood. The remedy is a correctly sized liner or a water heater that vents independently, verified with a spillage test and a carbon monoxide measurement in the room. That work belongs to a licensed plumber or your own heating contractor. Keeping the furnace as dual fuel backup avoids the issue entirely.
Who does gas to heat pump conversions in Prince George's County?
TerraStream Energy converts homes off gas or oil heat onto electric heat pumps and replaces whole heating and cooling systems, across Maryland with Prince George's County first, on single family houses. Equipment installed is Daikin and Goodman on R-32 refrigerant. The site visit covers the pad, the line set, the coil cabinet, the furnace data plate, the flue and the panel, then sizing from a room by room load calculation. Call 703-772-5970 to have a dead condenser and an aging furnace looked at in the same visit.